Product Details
Place of Origin: China
Brand Name: RION
Certification: CE, ISO,ROHS
Model Number: PDA826FL
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: packing carton
Delivery Time: 5~8 work days
Payment Terms: T/T
Supply Ability: 1000 pcs/month
Resolution: |
0.0005 |
Measure Accuracy: |
0.05 |
Output Options: |
RS485, RS422, RS232 (optional) |
Wide Voltage Input: |
DC 9~36V |
Weight: |
≤400g (Excluding Cable) |
Shockproof: |
100g@11ms / 3 Axial Direction (Half Sinusoid) |
Resolution: |
0.0005 |
Measure Accuracy: |
0.05 |
Output Options: |
RS485, RS422, RS232 (optional) |
Wide Voltage Input: |
DC 9~36V |
Weight: |
≤400g (Excluding Cable) |
Shockproof: |
100g@11ms / 3 Axial Direction (Half Sinusoid) |
APPLICATION FIELD
MAIN FEATURES
SPECIFICATIONS
| PDA826FL | Condition | Parameters | Unit |
| Measure range | - | ±10 | ° |
| Measure axis | - | XY | axis |
| Resolution | - | 0.0005 | ° |
| Measure accuracy | Room temp. | 0.05 | ° |
| Zero temp coefficient | -40~85℃ | 0.0003 | °/℃ |
| Sensitivity temp. coefficient | -40~85℃ | ≤50 | ppm/℃ |
| Power on time | <0.5 | S | |
| Response frequency | 20 | Hz | |
| Output rate | 5Hz / 10Hz / 25Hz / 35Hz / 50Hz / 100Hz Can be set | ||
| Output signal | RS485/RS232/RS422 Optional | ||
| EMC | According to EN61000 and GBT17626 | ||
| MTBF | ≥98000 hour/time | ||
| Insulation Resistance | ≥100 MΩ | ||
| Shockproof | 100g@11ms / 3 Axial Direction (Half Sinusoid) | ||
| Anti-vibration | 10grms / 10~1000Hz | ||
| Protection grade | IP67 | ||
| Cables | Standard 1 meter long wear-resistant, wide temperature, shielded cable, aviation connector, weight ≤150g | ||
| Weight | ≤400g (Excluding cable) | ||
|
Resolution: The smallest change in the measured quantity that a sensor can detect and distinguish within its measurement range. Accuracy: The accuracy value obtained by measuring multiple angle points within the measurement range. Zero-point temperature coefficient: The rate of change of the sensor's reading relative to room temperature within its rated operating temperature range when the sensor is at zero. Sensitivity temperature coefficient: The rate of change of the sensor's full-scale reading relative to its full-scale reading at room temperature within its rated operating temperature range as a percentage of temperature. |
|||
WIRING DEFINITION
S232 wiring definition (7-core wiring definition)
| Line color function | PIN1 | PIN2 | PIN3 | PIN4 | PIN5 | PIN6 | PIN7 |
| DC9~36V | GND | RXD | TXD | Signal ground | Factory use | ||
RS485 wiring definition (7-core wiring definition)
| Line color function | PIN1 | PIN2 | PIN3 | PIN4 | PIN5 | PIN6 | PIN7 |
| DC9~36V | GND | D+ | D- | Signal ground | Factory use | ||
RS422 wiring definition (9-core wiring definition)
| Line color function | PIN1 | PIN2 | PIN3 | PIN4 | PIN5 | PIN6 | PIN7 | PIN8 | PIN9 |
| DC9~36V | GND | RXD+ | RXD- | TXD+ | TXD- | Signal ground | Factory use | ||
INSTALLATION PRECAUTION
Please install the tilt sensor according to the correct method. Incorrect installation will cause measurement errors. Pay special attention to one "surface" and two "line":
INSTALLATION
During installation, the sensor installation surface should be kept parallel to the measured target surface to reduce the impact of dynamics and acceleration on the sensor; Please refer
Frequently Asked Questions About Inclinometers for Dam Monitoring
1. What type of sensor is used for dam tilt monitoring?
Dual-axis inclinometers are commonly considered for dam tilt monitoring because they measure inclination changes in two directions. The PDA826FL is a dual-axis inclinometer designed for slowly changing tilt measurement and low-frequency dynamic applications.
2. Can the PDA826FL be used for dam structural monitoring?
Yes. The PDA826FL can be used to measure inclination changes at designated positions on dam structures. Its measurement data can be collected and analyzed as part of a structural monitoring system.
3. What is the resolution of the PDA826FL inclinometer?
The PDA826FL has a resolution of 0.0005° and a measurement range of ±10°. Resolution should not be confused with measurement accuracy.
4. Does the PDA826FL support RS485 communication?
Yes. The PDA826FL offers optional RS485, RS422 and RS232 interfaces and supports the MODBUS industrial communication protocol.
5. Can the PDA826FL operate in outdoor environments?
The PDA826FL has an operating temperature range of -40°C to +85°C. It undergoes full temperature range calibration and compensation before delivery, making it suitable for applications involving changing ambient temperatures.
6. Is the PDA826FL suitable for long-term dam inclination monitoring?
The PDA826FL undergoes long-term stability testing before leaving the factory. It can be considered for long-term dam inclination data acquisition systems. Actual monitoring performance depends on installation conditions, system design and maintenance requirements.
7. How is the PDA826FL installed for dam monitoring?
The product is designed for horizontal installation and can be fixed to the designated measurement surface. The installation orientation and mounting structure should be determined according to the monitoring position and engineering requirements.