Product Details
Place of Origin: China
Brand Name: RION
Certification: CE, ISO,ROHS
Model Number: PDA826FL
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: packing carton
Delivery Time: 5~8 work days
Payment Terms: T/T
Supply Ability: 1000 pcs/month
Resolution: |
0.0005 |
Response Frequency: |
20Hz |
Output Signal: |
RS485/RS232/RS422 Optional |
Anti-vibration: |
10grms / 10~1000Hz |
Protection Grade: |
IP67 |
Wide Voltage Input: |
DC 9~36V |
Resolution: |
0.0005 |
Response Frequency: |
20Hz |
Output Signal: |
RS485/RS232/RS422 Optional |
Anti-vibration: |
10grms / 10~1000Hz |
Protection Grade: |
IP67 |
Wide Voltage Input: |
DC 9~36V |
APPLICATION FIELD
Key Benefits for Railway Infrastructure Monitoring:
SPECIFICATIONS
| PDA826FL | Condition | Parameters | Unit |
|---|---|---|---|
| Measure range | - | ±10 | ° |
| Measure axis | - | XY | axis |
| Resolution | - | 0.0005 | ° |
| Measure accuracy | Room temp. | 0.05 | ° |
| Zero temp coefficient | -40~85℃ | 0.0003 | °/℃ |
| Sensitivity temp. coefficient | -40~85℃ | ≤50 | ppm/℃ |
| Power on time | <0.5 | S | |
| Response frequency | 20 | Hz | |
| Output rate | 5Hz / 10Hz / 25Hz / 35Hz / 50Hz / 100Hz Can be set | ||
| Output signal | RS485/RS232/RS422 Optional | ||
| EMC | According to EN61000 and GBT17626 | ||
| MTBF | ≥98000 hour/time | ||
| Insulation Resistance | ≥100 MΩ | ||
| Shockproof | 100g@11ms / 3 Axial Direction (Half Sinusoid) | ||
| Anti-vibration | 10grms / 10~1000Hz | ||
| Protection grade | IP67 | ||
| Cables | Standard 1 meter long wear-resistant, wide temperature, shielded cable, aviation connector, weight ≤150g | ||
| Weight | ≤400g (Excluding cable) | ||
Resolution: The smallest change in the measured quantity that a sensor can detect and distinguish within its measurement range. | |||
MECHANICAL PARAMETERS
INSTALLATION PRECAUTION
Please install the tilt sensor according to the correct method. Incorrect installation will cause measurement errors. Pay special attention to one "surface" and two "line":
INSTALLATION
During installation, the sensor installation surface should be kept parallel to the measured target surface to reduce the impact of dynamics and acceleration on the sensor; Please refer to the following diagram for installation instructions:
1. Can the PDA826FL be used for high-speed railway infrastructure tilt monitoring?
Yes. The RION PDA826FL dual-axis dynamic inclinometer can be used in railway infrastructure monitoring applications where inclination changes need to be measured. It is suitable for monitoring selected structural components and trackside structures requiring low-frequency tilt measurement.
2. What railway infrastructure can the PDA826FL monitor?
The PDA826FL can be considered for inclination monitoring of suitable railway infrastructure components, such as monitoring supports, structural platforms, and selected trackside engineering structures. The installation location should be selected according to the specific monitoring requirements.
3. Why is low-frequency measurement important for railway infrastructure monitoring?
Low-frequency measurement helps capture slowly changing inclination signals caused by gradual structural movement or changes in supporting structures. This information can support long-term railway infrastructure monitoring and engineering analysis.
4. Does the PDA826FL support dual-axis inclination measurement?
Yes. The PDA826FL provides dual-axis inclination measurement with a measuring range of ±10° and a resolution of 0.0005°, allowing inclination changes to be measured along two axes.
5. Which communication interfaces are available for railway monitoring systems?
The PDA826FL supports the industrial MODBUS communication protocol. RS485, RS422, and RS232 interfaces are available as optional configurations for integration with compatible railway monitoring and data acquisition systems.
6. Can the PDA826FL provide real-time monitoring data?
Yes. The accompanying PC analysis software supports real-time measurement data display, recording, and analysis, helping engineers review inclination measurement results.
7. Can the PDA826FL operate in outdoor railway environments?
The PDA826FL has an operating temperature range of -40°C to +85°C. It also undergoes full-temperature-range calibration and compensation and long-term stability testing before delivery. The installation enclosure and environmental protection requirements should be evaluated according to the actual outdoor installation conditions.
8. How is the PDA826FL installed on railway infrastructure?
The PDA826FL is mounted on a suitable structural surface using screws. Proper horizontal orientation and secure mechanical installation are important for reliable inclination measurement. The installation position should be determined based on the monitoring target and engineering requirements.
Looking for a dual-axis inclinometer for railway infrastructure monitoring? Contact RION to discuss your measurement requirements and sensor integration options.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews