AKC370 Triaxial MEMS Vibration Sensor for Bridge impact monitoring  with 200Hz

Product Details

Place of Origin: China

Brand Name: RION

Certification: CE, ISO,ROHS

Model Number: AKC370

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: packing carton

Delivery Time: 5~8 work days

Payment Terms: T/T

Supply Ability: 1000 pcs/month

Get Best Price
Contact Now
Specifications
Highlight:

Triaxial MEMS vibration sensor

,

Bridge impact monitoring sensor

,

200Hz vibration sensor

Supply Voltage:
9-36V DC
Bandwidth:
200Hz @ 3Db
Measuring Axis:
X,Y,Z Axis
Measurement Range:
±2g~±16g
Protection Class:
IP67
Resolution:
<1mg
Supply Voltage:
9-36V DC
Bandwidth:
200Hz @ 3Db
Measuring Axis:
X,Y,Z Axis
Measurement Range:
±2g~±16g
Protection Class:
IP67
Resolution:
<1mg
Description
AKC370 Triaxial MEMS Vibration Sensor for Bridge impact monitoring  with 200Hz

What the AKC370 Vibration Sensor actually solves

Most vibration sensing projects stall on the conditioning electronics, not on the sensor. The AKC370 removes that entire layer: it is a complete 3-axis measurement chain in a sealed housing, and it outputs a voltage your existing data logger can already read.

DC to 200 Hz in one device

An integrated low-pass filter defines the band, so structural sway at 0.5 Hz and bearing noise around 150 Hz land in the same recording without swapping hardware.

True 3-axis sensing

X, Y and Z share one MEMS die and one temperature-compensated signal path, so cross-axis phase stays aligned — no three separate sensors to synchronise.

Rugged where it is mounted

Aluminium housing, IP67 sealing, 100 g shock survival with sub-millisecond recovery, and operation from −40 to +85 °C on machines that are never indoors.

Self-test as a commissioning step

Grounding the ST line makes every axis emit a ±1 g, 10 Hz square wave — proof the sensor and the whole output path are alive before you trust the data.

Low power, wide supply

35–38 mA at 12 V over a 9–36 V input — it runs from the same 24 V rail as the rest of the panel without a dedicated DC/DC.

EMC and RFI shielded

Shielded electronics and a metal body keep variable-frequency drives and radio equipment from writing noise into your acceleration trace.

APPLICATION SCOPE

  • ★ Bridge impact monitoring
  • ★ Machine control
  • ★ Structural monitoring
  • ★ Low-frequency vibration monitoring
AKC370 Triaxial MEMS Vibration Sensor  for  Bridge impact monitoring  with 200Hz

SPECIFICATIONS

AKC370 Parameters
Measurement Range ±2g~±16g
Measuring Axis X,Y,Z Axis
Resolution <1mg
Zero-Point Acceleration 2.5V (Voltage Output)
Full-Range Output 0.5-45V (Voltage Output)
Linearity 1%
Power-On/Power-Off Repeatability <2mg
Response Frequency 0 - 200Hz Integrated low-pass filter
Bandwidth 200Hz @ 3Db
Shock >100g@11ms (half sine wave)
Shock Recovery Time <1 ms
Operating Temperature Range -40~+85℃
Storage Temperature Range -40~+85℃
Supply Voltage 9-36V DC
Maximum Power Consumption 35-38mA @12V DC
Noise Density <25µg/√ Hz @ ±2g <60µg/√ Hz @ ±16g
Maximum Calibration Uncertainty <1mg
Electrical Protection EMC and RFI shielding
Reliability MIL-HDBK-217 Level 2
Self-Test ±1g @ 10Hz ST line grounding
Protection Class IP67
Product Dimensions L55×W37×H29mm
Product Weight ≤100g(excluding cable)

ELECTRICAL PARAMETERS

PIN

Definition

PIN1

PIN2

PIN3

PIN4

PIN5

Vcc 9~36V

X-axis output

Y-axis output

GND

Z-axis output

AKC370 Triaxial MEMS Vibration Sensor  for  Bridge impact monitoring  with 200Hz

SELF-TEST FUNCTION

  1. Self-Test Operation
  2. - Short-circuit the self-test cable (Self-Test) to ground (GND). The sensor enters self-test mode.
  3. - At this time, the X, Y, and Z axis output terminals will generate ±1g and 10Hz square wave signals respectively, used to verify whether the sensor and output circuit are working properly.
  4. Self-Test Completion
  5. - After the self-test is complete, the self-test cable must be left floating (disconnected from GND).
  6. Precautions for Use
  7. - During normal operation, the self-test cable must be kept floating; otherwise, measurement accuracy will be affected.
  8. - Do not short-circuit the self-test cable to the power supply (Vcc), as this may damage the sensor.

INSTALLATION DIRECTION

AKC370 Triaxial MEMS Vibration Sensor  for  Bridge impact monitoring  with 200Hz
Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send