Product Details
Place of Origin: China
Brand Name: RION
Certification: CE, ISO,ROHS
Model Number: AKP342
Document: AKP342 Wind Turbine Dedicat...or.pdf
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: $268.00/Pieces
Packaging Details: packing carton
Delivery Time: 5~8 work days
Payment Terms: T/T
Supply Ability: 1000 pcs/month
Measure Axial Direction: |
X,Y,Z |
Bandwidth (3DB): |
0.1~10HZ |
Wide Voltage Input: |
DC 9 ~ 36V |
Resolution: |
1ug |
Protection Class: |
IP 67 |
Output Rate: |
5Hz、10Hz、25Hz、35Hz、50Hz、100Hz |
Measure Axial Direction: |
X,Y,Z |
Bandwidth (3DB): |
0.1~10HZ |
Wide Voltage Input: |
DC 9 ~ 36V |
Resolution: |
1ug |
Protection Class: |
IP 67 |
Output Rate: |
5Hz、10Hz、25Hz、35Hz、50Hz、100Hz |
APPLICATION
WORKING PRINCIPLE OF VIBRATION
It adopts imported core control unit and uses the principle of capacitive miniature pendulum. According to the gravity principle of the earth, the gravity of the earth can generate a gravity component on a corresponding pendulum when the obliquity motion is inclined, the corresponding capacitance can be changed, and the acceleration can be obtained by amplifying, filtering and converting the capacitance. The frequency is obtained by algorithm processing and data analysis according to the collected acceleration. Amplitude data information.
INSTALLATION DIRECTION
During installation, keep the mounting surface of the sensor parallel to the surface of the target to be measured, so as to reduce the influence of dynamic and acceleration on the sensor. This product can be installed horizontally or vertically. Please refer to the following schematic diagram for the installation method:
![]()
PRODUCTION INSTALLATION NOTES
Please install the tilt sensor according to the correct method. Incorrect installation will lead to measurement errors. Pay special attention to one "surface" and two "lines":
![]()
FEATURES
SPECIFICATIONS
| AKP342 | Parameter | Unit |
| Range | ±2 | g |
| Deviation calibration | <1 | mg |
| Measure axial direction | X,Y,Z | Shaft |
| Repeatability of power-up/power-down | <2 | Mg (Max) |
| Temp coefficient of deviation | 0.15 | Mg/℃ (typical) |
| Resolution | 1 | ug |
| Nonlinearity | <1 | % FS (Max) |
| Bandwidth (3DB) | 0.1~10 | Hz |
| Cross-axis sensitivity | 1 | % |
| Transverse vibration sensitivity ratio | 1 | % |
| Noise density | 21 | μg/√Hz |
| Resonant frequency | 2.4 | kHz |
| Acceleration power-up settling time | 1S | |
| FFT power-up settling time | 30S | |
| Output rate | 5Hz,10Hz,25Hz,35Hz,50Hz,100Hz | |
| Output interface | RS232/TTL/S485 | |
| Communication protocol | 68 Protocol and MODBUS RTU Protocol | |
| Input (VDD _ VSS) | 9~36 VDC | |
| Operating current consumption | <16mA @ 12 VDC | |
| Weight | ≤ 400g (excluding cable) | |
MECHANICAL PARAMETERS
![]()